1. Industrial Central Air Conditioners Offers
  2. sku: 1941580260163262
  3. BALTIMORE AIRCOIL 95600681

BALTIMORE AIRCOIL COMPANY 95600681 Tower Cooling 3514

95600681 3514 Baltimore Aircoil Company Cooling Tower

( Brand: Baltimore Aircoil Company ), ( Manufacturer Part Number: 95600681 ), ( Model: 3514 ), ( Country//region Of Manufacture: United States )

Review BALTIMORE AIRCOIL COMPANY Tower Cooling

Product Name: 95600681 3514 Tower Air Cooled Heat Exchanger by Baltimore Aircoil

This 95600681 3514 Tower Air Cooled Heat Exchanger, manufactured by Baltimore Aircoil, is a high-performance cooling solution designed for industrial and commercial applications. Metering pump cooling, process cooling, and HVAC system cooling are just a few of the numerous applications where this air cooled heat exchanger can be effectively used.

The heat exchanger features a robust, all-aluminum construction with dimensions of 49.8 inches in height, 14.6 inches in width, and 10.2 inches in thickness. This compact design ensures minimal footprint while providing impressive cooling capacity. The cooling tower comes with five fan sections, which are equipped with backward-inclined fans configured for optimum airflow distribution. The fan motors are TEFC (totally enclosed fan cooled) with Class F insulation for longer lifesome and improved energy efficiency.

The Baltimore Aircoil 95600681 3514 comes with a 35-degree, counter-flow fill plate design. This configuration ensures improved heat transfer efficiency by minimizing the contact between hot and cold fluids and maximizing turbulence in the fill material. Filles material in this heat exchanger is thermal plastic, making it resilient and well-suited for handling corrosive liquids.

Adding to its stability and longevity, this cooling tower is outfitted with rubber isolation mountings and a rust-resistant galvanized steel base to help minimize vibration and structural damage. The unit comes with multiple access door configurations to ensure ease of access for maintenance, while its debris gate prevents large debris entry and safeguards the internal components.

Operating in temperatures ranging from 20 F to 120 F ( 1 C to 49 C), this air cooled heat exchanger delivers a cooling capacity of 520,000 BTUH (168,000 W). Live loading components have a maximum operating pressure of 125 psig and 150 F (8.62 bar and 66 C). This cooling tower is also OSHA, CE, Mexican Standard NOM-138-SSA1-2010 compliant, ensuring stringent safety and performance standards.

Designed for optimal reliability and minimal maintenance, the Baltimore Aircoil 95600681 3514 is an impressive cooling solution that offers high efficiency and durability, making it a cost-effective investment for applications requiring efficient heat exchange capabilities.

Pros and Cons of Buying a 3514 Tower Air Cooler by Baltimore Cooling (Model 956.006.81)

Introduction:

The 3514 Tower Air Cooler by Baltimore Cooling is a popular option for those seeking a cost-effective and energy-efficient cooling solution. Here, we will discuss some of its key advantages and disadvantages to help you make an informed purchasing decision.

Pros:

1. Energy Efficiency: Baltimore Cooling's 3514 Tower Air Cooler features a modern design with high-performance fans that provide excellent cooling capacity with minimal energy consumption.

2. Cost-Effective: Compared to traditional HVAC systems, air coolers like the 3514 model from Baltimore Cooling offer significant cost savings due to their lower installation and operational expenses.

3. Portability: Its compact size and rollable design make it a convenient option for both residential and commercial settings, allowing easy relocation for event spaces or temporary applications.

4. Cost-efficient Water Usage: Air coolers do not require the use of expensive refrigerants or compressors, as they utilize water evaporation for cooling.

5. Low Maintenance: The 3514 Tower Air Cooler has minimal parts needing regular replacement, saving you time and money on maintenance costs.

Cons:

1. Dependence on Ambient Air: Air coolers rely on outside air to function effectively, and performance may be impacted by low humidity or high ambient temperatures.

2. Limited Cooling Capacity: Smaller tower air coolers like the 3514 model may not be suitable for large spaces or intense heat conditions (above 95 F).

3. Noise Level: The fan of the 3514 Tower Air Cooler may produce a noticeable noise level when running at higher settings, which could be a concern for some users in residential settings.

4. Winter Performance: Air coolers are not designed for cooling in the winter months, so users living in colder climates may not benefit from this cooling system year-round.

Conclusion:

The Baltimore Cooling 3514 Tower Air Cooler provides several benefits, including energy efficiency, cost-effectiveness, and portability, making it an attractive choice for those looking for a reliable and affordable cooling solution. However, it may not be suitable for spaces with high cooling demands or those living in colder climates. It is essential to consider the pros and cons, such as performance in various conditions, cooling capacity, and noise levels, before making a final purchasing decision.

Recommendation:

The 3514 Tower Air Cooler from Baltimore Cooling is an excellent option for those seeking a budget-friendly and energy-efficient cooling system for smaller spaces, provided they are willing to accept the limitations outlined above. Before purchasing, ensure it meets your specific cooling requirements and ambient conditions. If your cooling needs are more extensive, you may want to consider alternative options such as traditional HVAC systems or larger air coolers.

Details:

Across wet deck surface patented the standard polyvinyl chloride PVC across wet deck surface is designed for maximum heat transfer with low fan power requirements. Bulletproof unique b.

The entering water temperature must not exceed 120 degrees f or damage to the wet deck material may occur, resulting in lost cooling efficiency. Model no 5514serial no 95600681belt no b5144 manufacturer's published thermal performance is certified by the cooling tower institute under the provisions of std c.

Engineered drive system consists of a specially designed belt, a corrosion resistant fan sheave, and a motor sheave in a vented enclosure.

part #: 95600681 prices

  • $6.00-$46.83

specifications acrfrigeratio:

  • brand: Baltimore Aircoil Company
  • mpn: 95600681
  • model: 3514
  • country//region of manufacture: United States

Returns acrfrigeratio:

  • policy: no returns

Payments acrfrigeratio:

  • PayPal

Ratings:

  1. Seller failed to complete sale after offering items for sale. 01-18-16
  2. Great Seller!!! 01-27-16
  3. A1 03-04-16

Offer acrfrigeratio:

  • Started: March 30, 2016, 9:15 am
  • quantity: 1
  • # Sold: 0
  • # bids: 0
  • best offer: true

Seller acrfrigeratio:

  • zipcode: 73105
  • city: Oklahoma City, Oklahoma

General acrfrigeratio:

  • Business & Industrial > MRO & Industrial Supply > HVAC > HVAC Units > AC & Refrigeration Units
  • in stock: Yes
  • condition: Used

Shipping acrfrigeratio:

  • type: NotSpecified
country//region of manufacture: united states,
category: business & industrial > hvac > hvac units > ac & refrigeration units, sku: 1941580260163262,
Review#1 Seller failed to complete sale after offering items for sale. ()
Review#2 Great Seller!!! ()
Review#3 A1 ()
Baltimore Aircoil Company 95600681 Is Similar To:
acrfrigeratio logo
4 offers $6.00–$46.83 USD
  • New. Offer #1 priced at $46.83 + $10.00 shipping estimate = $56.83* total. Worldwide ---- NOT AVAILABLE.+$10.00 shipping
  • Used. Offer #2 priced at $6.00 + $5.62 shipping estimate = $11.62* total. Print Date: 1970s-1980s. Photo Date: Fall 1967.+$5.62 shipping
  • Used. Offer #3 priced at $7.00 + $5.62 shipping estimate = $12.62* total. Photo Date: 11/7/64.+$5.62 shipping
  • Offer #4 priced at $24.99 + $6.50 shipping estimate = $31.49* total. +$6.50 shipping

Copyright © acrfrigeratio.com