( Brand: Carrier ), ( Manufacturer Part Number: WEATHERMAKER ), ( Model: 48TCDD12A2A6A0A0A0 ), ( Part Type: Unit ), ( Voltage Required: 460v 3 Phase ), ( Refrigerant Type: R-410a )
The 48TCDD12A2A6A0A0A0 is a robust and efficient 10 kW data center cooling unit, specifically designed to deliver reliable cooling solutions for mission-critical IT environments. This cooling unit, with the product code 48TCDD12A2A6A0A0A0, is engineered to meet the demands of modern data centers, providing precise temperature control, high airflow capacity, and energy efficiency.
Design and Construction:The cooling unit features a robust and compact design with a dimension outline of (HxWxD): 48 inches (1219.2 mm) high, 12 inches (304.8 mm) wide, and 30 inches (762 mm) deep. Constructed with durable materials, the unit can effectively dissipate heat and protect rack mount IT equipment against overheating. Its modular design enables easy upgrades and maintenance.
Cooling Capacity and Performance:This 10 kW data center cooling unit offers an impressive thermal capacity that effectively maintains temperature and humidity levels within the recommended range for optimal IT system performance. Rated at an efficient cooling capacity of 10,000 BTUs per hour, the unit delivers the required cooling power to ensure high availability and prevent data center downtime.
Integrated Controls and Energy Efficiency:Equipped with intelligent control features, the cooling unit continuously monitors enclosure temperature and adjusts cooling output accordingly, conserving energy and maintaining overall efficiency. The hot and cold aisle containment design as well as the economizer function further contribute to energy cost savings by utilizing outside air when conditions allow, thereby reducing the cooling load on the unit.
Versatile Mounting Configuration:The 48TCDD12A2A6A0A0A0 data center cooling unit provides flexible installations options, with support for top and rear air intake configurations or side intake. The included adjustable support rails allow for customized installation in various rack setups and configurations.
Reliability and Quality:Designed with industry-standard components, this cooling unit ensures high reliability, longevity, and low maintenance, providing an excellent value proposition for data center operators seeking Full Cabinet Cooling solutions. Additionally, the unit complies with industry safety standards, ensuring the protection of both the equipment and personnel surrounding the cooling unit.
In conclusion, the 48TCDD12A2A6A0A0A0 10 kW data center cooling unit is an essential component for any modern data center seeking high capacity cooling solutions, reliable temperature control, and energy efficiency. With a compact design, flexible mounting configurations, and intelligent control features, the unit offers a versatile and effective solution to meet the cooling demands of today's data center environment.
The Carrier 48TCDD12A2A6A0A0A0 10 460 unit is a commercial-grade air conditioning system designed for large data centers or server rooms. It offers high cooling capacity and efficiency, making it a popular choice for businesses with significant IT infrastructure. In this analysis, we will discuss the key pros and cons of investing in this cooling unit.
Pros:1. High Cooling Capacity: With a cooling capacity of up to 460 tons, this unit is capable of handling the cooling demands of large data centers or server rooms effectively.
2. Energy Efficiency: The high-efficiency design of the Carrier 48TCDD12A2A6A0A0A0 ensures minimized energy consumption and reduced operational costs.
3. Enhanced Condenser Performance: The unit features a two-stage compressor, which delivers better condenser performance, ensuring a consistent and reliable cooling process.
4. Improved Airflow: The enhanced airflow design of this cooling system minimizes temperature stratification and hotspots in the data center or server room.
5. Integrated Service Feature: The unit comes with a built-in service feature, which aids in diagnosing faults and optimizing performance.
Cons:1. Complex Installation: Installing the 48TCDD12A2A6A0A0A0 10 460 unit requires professional expertise and resources, which can result in higher upfront costs.
2. Cost: The high-performance compressors and the large capacity of the unit result in a higher cost compared to standard air conditioning systems.
3. Size: Given the high cooling capacity, the unit is comparatively large and may occupy significant space within the data center or server room.
Conclusion:The Carrier 48TCDD12A2A6A0A0A0 10 460 unit cooling system can be a valuable investment for businesses with substantial IT infrastructure due to its high cooling capacity, energy efficiency, enhanced airflow, and reliable condenser performance. However, the complex installation process, higher upfront costs, and large size may deter some potential buyers. Ultimately, it is essential to carefully consider the cooling requirements, cost constraints, and available installation resources before making a decision to invest in this unit.
Recommendation:If your business requires a high-performance cooling solution to maintain an efficient data center or server room, the Carrier 48TCDD12A2A6A0A0A0 10 460 unit cooling system could be an excellent investment for ensuring optimal cooling conditions for your IT infrastructure. However, it is strongly recommended to consult with a professional HVAC company for expert advice on installation, potential cost savings, and the optimal placement of this large cooling unit within your facility.
If your call is not answered, please leave a message and someone will return your call. Solemnized heat exchange, 5 yr.
Our no strip screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit metal. Each circuit is protected with a high and low pressure switch.
This makes service, stocking parts, replacement, and troubleshooting easier. seer up to ton units fit on existing Carrier rooftop curbs. Sloped, composite drain pan sheds water and won't rust. Take accurate pressure readings by reading condenser pressure with panels on.
Easy to install all Weathermaker units are field convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications.
Single, central terminal board for test and wiring connections.
Standard parts only warranty 10 yr.
Mechanical cooling 115 f to 40 f or 46 c to 4 c standard on all model's. Easy adjust, belt drive motor available. This is a medium static unit is also has the low heat option.
Ovation condenser coil, 1 yr.
Field convertible airflow ton. Most problems can be worked out if we just communicate. Carrier designed naturally draining heat exchange, unlike positive pressure heat exchanges, do not need to be periodically, manually drained.
Standardized components and layout. Clean, large, easy to use control box.erupt to 11.
Standardized controls control box layout. Easy to maintain easy access handles by Carrier provide quick and easy access to all normally serviced components.
Available on 2 stage cooling model's with controls or rut open.. The technician who installs the equipment can assist you in getting it registered for warranty. This saves time and money on replacement jobs.
Wades will personally warranty all parts for 1 year from date of purchase. This saves labor and maintenance expense. Many factory installed options ranging from air management economizers, 2 position dampers, plus convenience outlet's, disconnect switches and smoke detectors.
Irrupt to 11. Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. Provisions for bottom or side condensate drain.
Standardized components controls make stocking parts service easier. Truck drivers will try to rush you, take your time and make a complete inspection.
No strip screw system guides screws into the panel captures them tightly without stripping the screw, the panel, or the unit.
Fast access, handled, panels for easy access on normally accessed service panels. Standardized components and controls make service and stocking parts easier. Two cooling stage model's are available from 7.
Simply remove the black, composite plug, route your gauge line through the hole, and connect them to the refrigeration service valve Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
Scroll compressors on all units. Optional staged air volume save system utilizes a variable frequency drive FD to automatically adjust the indoor fan motor speed between cooling stages. Capable of thru the base or thru the curb gas line routing.
Carrier rooftops have high and low pressure switches, a filter drier, and 2 in 51mm filters standard.
S refrigerant filter drier on each circuit. High efficiency, gas heat with induced draft flue exhaust design. Lighter rooftops make easier replacement jobs.
Tool less filter access door. 2 in 51mm disposable filters on all units. 15 ton model's require a simple supply duct cover to field convert from factory vertical to horizontal.
Features and benefits single cooling stage model's are available from ton.
Lighter units make easy replacement. Induced draft motor ensures no flue gas can escape into the indoor air stream. Factory installed humid misery adaptive humidification system on all sizes with round tube plate fin condenser coils, includes motor master I controller. Compressor, 3 yr.
8 with single speed indoor fan motor and up to ton.color coded wiring.
Most low voltage connections are made to the same board and make it easy to find what you re looking for and easy to access it. Winter start kit allows cooling operation down to 25 f 4 c and motor master to 20 f c.
Take pictures if possible.
The factory warranty is through the manufacturer and there is no warranty through us for equipment replacement parts etc. Single point gas electrical connection.
Also, our large control box gives you room to work and room to mount Carrier accessory controls. 8 with 2 speed FD indoor fan motor. Docs 1009 public 06 48tc 19pd.
This unit has two stages of cooling comes fully charged with r410.