( Brand: Beacon Morris ), ( Manufacturer Part Number: STC14355-05 ), ( Part Type: Heater ), ( Fin Material: Aluminum ), ( Inlet/outlet Npt: 1-1/4 ), ( Item: Steam/hydronic Heater Element ), ( Length: 5 Ft., Fluid 300 Degrees F, Heat/linear 150 F Water 960/1130 Btuh, Heat/linear 160 F Water 1130/1330 Btuh, Heat/linear 170 F Water 1300/1530 Btuh, Heat/linear 180 F Water 1470/1730 Btuh, Heat/linear 190 F Water 1660/1960 Btuh, Heat/linear 200 F Water 1830/2160 Btuh ), ( Pressure: 194 Psi ), ( Output 2 Psi Steam: 2130/2510 Btuh ), ( Tubing Material: Copper ), ( UPC: 790107004611 )
The STC14355-05 Beacon Morley Steam-Hydronic Heater Element is designed to provide efficient and reliable heating performance in various commercial and industrial applications. Here are its key features and specifications:
Design and Construction:The heater element is constructed with high-quality copper material, ensuring both durability and resistance to corrosion in steam and hydronic heating systems. It is available in a standard length of 5 feet (152.4 centimeters) to fit most steam and hydronic heating applications. The STC14355-05 model has an electrical resistance of 7.9 Ohms and carries the 790107004611 product number.
Functionality and Applications:This steam-hydronic heater element is designed to work in high-temperature environments and transfer heat from the steam or hot water through the conductive copper material. It is suitable for various applications, such as:
1. Industrial processes: For industrial applications requiring heating through steam or hot water, this heater element will ensure a consistent temperature, optimizing process efficiency and productivity.
2. HVAC systems: In hydronic heating, hot water is circulated through baseboards or radiators. The heater element converts electrical energy into heat, which is then transferred to the water. This process warms up the spaces in buildings and provides comfortable temperatures.
3. Food industry: In commercial kitchens and food processing industries, steam and hot water are essential for several applications, including cooking, cleaning, and sanitation processes. The STC14355-05 Beacon Morley Steam-Hydronic Heater Element is designed to ensure that these processes run smoothly and efficiently.
4. Laboratories: In laboratories, precise control of temperature is crucial for various applications. This heater element ensures an accurate and reliable heating solution during experiments that involve steam or hot water.
Safety and Compliance:The STC14355-05 Beacon Morley Steam-Hydronic Heater Element is designed to meet various safety standards, such as UL and CE. It has undergone rigorous testing to ensure compliance with relevant industry regulations and safety requirements. Additionally, proper installation, operation, and maintenance of the heater element will help prevent potential hazards, such as leaks, overheating, or electrical faults.
Overall, the STC14355-05 Beacon Morley Steam-Hydronic Heater Element is an essential component in a wide range of industrial and commercial applications where heat is required in steam or hydronic systems. Its superior copper construction, reliable performance, and compliance with various safety standards make it a top choice for those seeking efficient and dependable heating solutions.
a. High Heat Output: This heater element is designed to provide a high heat output, making it suitable for larger spaces or commercial applications where a large amount of hot water is required.
b. Durable Construction: The STC14355-05 Beacon Morris Steam-Hydronic Heater Element is constructed with copper, which is known for its durability and resistance to corrosion. This makes it a long-lasting solution for your heating needs.
c. Easy Replacement: If your existing heater element has failed, replacing it with a new one, such as the STC14355-05, can be a cost-effective solution.
d. Versatile Applications: This heater element can be used in various applications, including boilers,Calefaction systems, and steam turbines.
e. Energy Efficiency: A well-maintained and functioning heater element can help improve the energy efficiency of your heating system, saving you money on your energy bills in the long run.
2. **Cons:**a. High Initial Cost: The initial cost of purchasing a new heater element, like the STC14355-05, can be significant. However, the long-term savings and improved performance can outweigh this investment.
b. Complex Installation: Installing a new heater element, especially in a large or complex system, can be time-consuming and requires professional expertise. Be sure to consult a qualified technician for installation to ensure safety and optimal performance.
c. Potential Risk of Leaks: As a wet-end component, the heater element can potentially develop leaks over time. Be sure to regularly inspect the element for signs of leaks and address any issues promptly to prevent damage to the surrounding system.
d. Potential for Scaling: The STC14355-05, like other heater elements, can develop scaling on the heat transfer surface over time. This can affect the efficiency of theheater element and may require regular cleaning or descaling to maintain optimal performance.
In conclusion, the STC14355-05 Beacon Morris Steam-Hydronic Heater Element offers high heat output, durability, and versatility, making it an attractive option for commercial and large-scale heating applications. However, it may require professional installation, periodic inspection, and maintenance for optimal performance and longevity. Its high initial cost should also be considered along with the potential for leaks and scaling. Weighing these pros and cons can help you make an informed decision about this heater element for your specific heating needs.
Recommendation: If considering investing in the STC14355-05 Beacon Morris Steam-Hydronic Heater Element, ensure thorough research and consultation with a professional technician to understand the installation and maintenance requirements. This will help you make a well-informed investment and enjoy the benefits of energy efficiency and long-lasting performance.
Max f water temp. Tube size in btu h, max f water temp. Tubing material copper, fin aluminum, inlet outlet npt in btu h, max. Heat linear ft f water temp.
Heat linear ft btu h, max btu h. Pressure 194 psi, output 2 psi steam btu h, max. Steam hydronic heater element, length 5 ft. Heat linear ft degrees f, max.
Heat linear ft.