1. Industrial Central Air Conditioners Offers
  2. sku: 3483664166014371
  3. BALTIMORE AIR COIL FXT19

BALTIMORE AIR COIL FXT19 Bac Pump Fxt Cooling Tower

Fxt19 Baltimore Air Coil Bac Fxt Cooling Tower Includes Pump

( Brand: Baltimore Air Coil ), ( Model: FXT19 ), ( Part Type: Pump ), ( Country/region Of Manufacture: United States )

Review BALTIMORE AIR COIL Bac Fxt Cooling Tower Includes Pump

The FXT19 BAC Baltimore Aircoil cooling tower pump is a crucial component in the cooling system of industrial and large commercial HVAC applications. This high-performance pump is precisely engineered and manufactured by Baltimore Aircoil, a leading name in heat exchangers and cooling tower technology.

The FXT19 is a top-entry, vertical, volute pump designed for the efficient circulation of water in cooling towers. Its robust construction and advanced features make it ideal for handling large volumes of water and delivering reliable, consistent performance. The pump housing is made of cast iron, ensuring durability and resistance to corrosive environments, while the impeller and diffuser are crafted from high-strength, wear-resistant material.

Performance and efficiency are at the heart of the FXT19. The pump's design offers a flow rate ranging from 20 to 50 gallons per minute (75.7 to 189.3 liters per minute) and can handle total dynamic head up to 18 feet (5.5 meters). Its low NPSHr, together with its ability to function effectively even at very low NPSHa levels, makes it suitable for operation in a wide range of conditions. The FXT19 is also engineered to maintain hard suction and avoid cavitation, ensuring steady water flow and putting minimal stress on the rest of the cooling system.

Several design choices enhance the FXT19's ease of installation and maintenance. Its top-entry design allows simple access for inspection, repair, or replacement of mechanical components, reducing downtime and labor costs. Additionally, the pump includes a few optional features such as leak-detection systems and variable speed drives. These options enable improved energy efficiency and cleaning capabilities while reducing labor costs and system energy consumption.

In operation, the FXT19 adheres to stringent and often customizable noise reduction standards to minimize disruption in adjacent environments. Its solid motor enclosures ensure gross pollutant intake reduction, likewise contributing to a cleaner operation. The FXT19 BAC Baltimore Aircoil cooling tower pump is a dependable and cost-effective solution for cooling towers that require efficient circulation and consistent flow.

The FXT19 BAC Baltimore Aircoil cooling tower pump is a crucial component in the cooling process of a cooling tower system. Here are some pros and cons to help you make an informed decision about purchasing this particular pump:

Pros:

1. High Efficiency: The FXT19 pump is designed to ensure high pumping efficiency with its hydraulically-balanced, totally enclosed, and fan-assisted motor, which minimizes horsepower requirements and lowers operational costs.

2. Durability: The pump is built with a heavy-duty cast iron construction, providing durability and resistance to wear and tear, making it suitable for long-term use.

3. Low Noise: This pump is engineered for low noise operation, reducing operational disruptions and maintaining a peaceful work environment.

4. Versatile Applications: The FXT19 cooling tower pump can be used in various industrial, commercial, and institutional cooling applications.

5. Easy Installation: The unit's modular design allows for simple and quick installation with minimal site preparation needed.

6. Energy-efficient: This pump is designed with energy efficiency in mind, ensuring lower energy usage and utility bills over its lifetime.

Cons:

1. Higher Initial Cost: Compared to some alternative pump types, the FXT19 cooling tower pump can have a higher upfront investment cost.

2. Limited Capacity: The FXT19 pump has a maximum flow rate of 70 gallons per minute (GPM), which may not be suitable for larger cooling tower installations.

3. requires regular maintenance: Proper maintenance is essential to maximize the pump's performance and longevity, including routine inspections, cleaning, and potential part replacements.

Conclusion:

The FXT19 BAC Baltimore Aircoil cooling tower pump offers numerous advantages, such as efficiency, durability, low noise, versatility, and easy installation. While the upfront cost may be higher than some competitor models, its energy efficiency, robust construction, and reliability may make it a worthwhile investment for your cooling tower system. Moreover, the pump's modest flow rate and ongoing maintenance requirements should be taken into consideration when determining its suitability for your specific application.

Recommendation:

After analyzing the pros and cons, the FXT19 BAC Baltimore Aircoil cooling tower pump is a solid option for medium-sized cooling tower installations that require high efficiency, low noise, and durability. If you're seeking a cost-effective, yet reliable solution for efficient cooling tower operation, the FXT19 pump could be a good choice. Always consult with an industrial cooling professional to ensure this pump meets your specific requirements before making a purchasing decision.

Details:

Sold in the as-is condition. Unit appears to be complete and in good condition. This listing is for a used bac Baltimore Air Coil cooling tower.

part #: fxt19 prices

  • $749.99-$11399.99

specifications acrfrigeratio:

  • brand: Baltimore Air Coil
  • model: Fxt19
  • part type: Pump
  • country/region of manufacture: United States

Shipping acrfrigeratio:

  • type: NotSpecified

Payments acrfrigeratio:

  • PayPal

General acrfrigeratio:

  • condition: Used
  • business industrial > mro industrial supply > hvac > hvac units business industrial > acrefrigeration units hvac units
  • in stock: Yes

Ratings:

  1. Super fast payment. Thank you for your purchase. 12-14-17
  2. Great communication. A pleasure to do business with. 11-27-17
  3. Very fast payment. Thanks! 12-27-17
  4. A Buyer Fast Payment! 11-27-17
  5. Very nice with fast transaction and nice items. 05-02-18

Returns acrfrigeratio:

  • policy: no returns

Offer acrfrigeratio:

  • bids: 0
  • Sold: 0
  • Started: July 14, 2018, 4:30 am
  • best offer: true
  • quantity: 1

Seller acrfrigeratio:

  • zipcode: 48218
  • city: River Rouge, Michigan
part type: pump, country/region of manufacture: united states,
category: business & industrial > hvac > hvac units business industrial > acrefrigeration units hvac, sku: 3483664166014371,
Review#1 Super fast payment. Thank you for your purchase. ()
Review#2 Great communication. A pleasure to do business with. ()
Review#3 Very fast payment. Thanks! ()
Review#4 A Buyer Fast Payment! ()
Review#5 Very nice with fast transaction and nice items. ()
Baltimore Air Coil FXT19 Is Similar To:
  • (41.4% similar) Bac Baltimore Airfoil cooling tower 244 tons model fxt 1212C 24D30 hp volt pumps size 1510 bf...(August 11th, 2015)
  • (34.1% similar) Was in operation this summer when our chiller took a dump. But this is a good solid unit. Contact me for more details. In enclosure it is impossible to get a picture of whole unit. I'll try from the roof of an adjacent building. Normal wear. Not rusted out. Media needs some cleaning and stuff like ...(November 19th, 2017)
  • (62.2% similar) Prices to be set after purchase. Manufacture: Baltimore Airfoil company model: 3333C-LM-2 serial U071882501 double cell unit. L 10'-820HP motor, pump, plumbing, etc...(July 6th, 2018)
  • (43.7% similar) Model 3455A-MM800 ton sized degree delta at 640 intact inside, free of all debris...(May 7th, 2017)
  • (63.1% similar) Make offer, must go. For sale is one used good working condition bac cooling tower being taken out of service because of a move and change of equipment...(November 12th, 2015)
  • (57.4% similar) English resource library file 545 . This machine can be seen by apt prior to buying. Motors premium efficient FD duty fan motors are standard. Owners save money while conserving natural resources and reducing environmental impact. All info should be independently verified. Benefits induced draft ...(October 29th, 2016)
  • (47.3% similar) GM of water from 128 f to 95 f at 80F entering Air wet bulb fan motors one hp fan motors, totally enclosed 1 speed 1 winding suitable for 460 volt, 3 phase, 60 hertz electrical service manufactured still installed at factory available for inspection equipment summary forced draft, counter flow ...(August 8th, 2016)
  • (53.2% similar) Rubber hose fittings and valves spare cooling tower drive shaft. Cooling tower control panel. German Krupp 10 model l pump 610 M20 b German Krupp 12' primary pump. Pact hep 60 hp lesson 60 hp...(December 28th, 2015)
  • (61.5% similar) All equipment sold as is and where is. Used bac cooling tower model 3501C serial U111101503 01 nominal tons 485 motor 30 hp year cross flow open loop galvanized top and bottom with fiberglass sides price is loaded on buyer truck...(April 4th, 2016)
  • (60.2% similar) Across wet deck surface patented the standard polyvinyl chloride PVC across wet deck surface is designed for maximum heat transfer with low fan power requirements. The entering water temperature must not exceed 120 degrees f or damage to the wet deck material may occur, resulting in lost cooling ...(March 30th, 2016)
  • (70.2% similar) Please with questions...(September 23rd, 2016)
acrfrigeratio logo
3 offers $749.99–$11399.99 USD
  • New – Open box. Offer #1 priced at $5184.50 + $0.00 shipping estimate = $5184.50* total. FREE SHIPPING
  • Used. Offer #2 priced at $749.99 + $Calculated shipping estimate = $749.99* total. +$Calculated shipping
  • Used. Offer #3 priced at $11399.99 + $Calculated shipping estimate = $11399.99* total. +$Calculated shipping

Copyright © acrfrigeratio.com