1. Industrial Central Air Conditioners Offers
  2. sku: 6541297357766121
  3. BALTIMORE AIR COIL VT1-340-PCR

BALTIMORE AIR COIL VT1-340-PCR Tank Cooling Tower

Vt1-340-pcr Tower Cooling Wet Tank Baltimore Air Coil

( Brand: Baltimore Air Coil ), ( Model: VT1-340-PCR ), ( Part Type: Tank )

Review BALTIMORE AIR COIL Wet Tank Cooling Tower

Product Description: Tank Cooling Baltimore Tower VT1-340-PCR Air Coil

The Tank Cooling Baltimore Tower VT1-340-PCR Air Coil is a state-of-the-art cooling solution designed to maintain optimal temperatures in large storage tanks and vessels. This air-cooled heat exchanger is an essential component for various industries, including petroleum, chemical, food processing, and pharmaceuticals, where temperature regulation is crucial for product quality and safety.

Design and Construction:

The VT1-340-PCR Air Coil is a vertical, air-cooled heat exchanger specifically designed to provide efficient and effective cooling for large tank applications. The tower measures 13 feet 6 inches in height and 1 foot 10 inches in width, with a fin height of 3 feet and a fin pitch of 1.5 inches. It is made of high-quality materials, such as carbon steel or stainless steel, depending on the specific application requirements. The tower utilizes a proprietary PCR (Plate Coil Removal) design, allowing for easy access to the internal coil, which enhances maintenance and cleaning.

Cooling Capacity:

The Baltimore Tower VT1-340-PCR Air Coil offers an impressive cooling capacity of 340 tons. Its large air flow rate, provided by multiple rows of high-density fins and efficient fan design, ensures that the cooling duty is met while maintaining a low approach temperature. This design provides a high level of temperature control and allows the tank or vessel to maintain the desired temperature, protecting the contents from deteriorating or degrading due to excessive heat.

High-Performance Fans:

The tower is equipped with high-performance, backward-inclined fans that ensure an adequate volume of air flows through the coil. The fans are designed to resist corrosion and offer a long lifespan, even in harsh environments. The fans are also equipped with adjustable pitch control, which can be used to optimize the fan performance based on changing ambient conditions.

Easy Maintenance:

The Baltimore Tower VT1-340-PCR Air Coil features easy-to-access components, including PCR coil removal and removable fan blades. This design makes routine maintenance tasks, such as cleaning and coil inspection, efficient and safe. The tower is also equipped with a self-draining design that prevents the accumulation of water on the fan blades and coil, ensuring a longer lifespan.

Durability and Reliability:

The Tank Cooling Baltimore Tower VT1-340-PCR Air Coil is engineered for durability and reliability. It is designed to withstand demanding operating conditions, including high humidity, heavy rain, and extreme temperatures. The tower undergoes rigorous testing to ensure it meets or exceeds industry standards for performance and safety. With consistent maintenance, the air coil is expected to provide dependable service for several years, ensuring optimal tank temperature and product quality.

In conclusion, the Baltimore Tower VT1-340-PCR Air Coil is an excellent choice for efficient and reliable cooling of large storage tanks and vessels. With its impressive cooling capacity, high-performance fans, easy maintenance, and durable design, it is the go-to solution for industries that demand precise temperature control.

Tank Cooling Baltimore Tower VT1-340-PCR Air Coil: Pros and Cons

The Baltimore Tower VT1-340-PCR air coil is a popular choice for tank cooling systems due to its durable design and efficient cooling capabilities. However, like any system or component, it comes with its advantages and disadvantages. Each organisation or individual considering the purchase of this air coil should consider the following pros and cons before reaching a decision.

Pros:

1. High Cooling Capacity: The Baltimore Tower VT1-340-PCR air coil offers a high cooling capacity, making it suitable for large-scale or high-heat applications.

2. Durability: The air coil is built with a robust, corrosion-resistant design, which enhances its longevity. This durability ensures that the air coil requires minimal maintenance and can withstand harsh operating conditions.

3. Scalability: The Baltimore Tower VT1-340-PCR air coil can be easily scaled to accommodate growing tank cooling needs, making it a cost-effective option for future expansion.

4. High Efficiency: The air coil features an efficient cooling process that minimises energy usage and, in turn, reduces operating costs. Its design allows for consistent, even heat transfer, ensuring optimal performance.

Cons:

1. Higher Upfront Cost: Compared to smaller, less powerful air coils, the Baltimore Tower VT1-340-PCR air coil comes with a higher upfront cost due to its size and capabilities.

2. Space Requirement: The large size of the air coil demands substantial space for installation, which might pose a challenge in facilities with limited space.

3. Complex Installation: Installing a Baltimore Tower VT1-340-PCR air coil requires a more intricate process compared to smaller systems due to its size and weight. This installation process might necessitate hiring professional help, increasing overall costs.

Conclusion:

In conclusion, the Baltimore Tower VT1-340-PCR air coil offers a robust, high-capacity tank cooling solution suitable for large-scale applications. Its durability and efficiency contribute to long-term savings on maintenance and energy costs while ensuring optimal performance. However, its higher upfront cost, complex installation process, and space requirements may make it a less ideal choice for smaller applications or budget-constrained operations. Ultimately, the decision to invest in the Baltimore Tower VT1-340-PCR air coil should be weighed against the specific cooling needs and resource considerations of each organisation.

Recommendation:

My recommendation would be for organisations requiring large-scale tank cooling solutions or high heat applications to consider the Baltimore Tower VT1-340-PCR air coil. Its high cooling capacity, durability, and efficient design make it a sound investment for long-term performance and cost savings. Conversely, small-scale operations or budget-constrained facilities might be better served exploring alternative, smaller and more cost-effective air coil options. Ultimately, the choice should depend on the unique cooling requirements and resources available to each organisation.

Details:

Baltimore Air Coil cooling tower with wet tank vt1 340 pcr, no pumps and needs new motor.

part #: vt1340 price

  • $11399.99

specifications acrfrigeratio:

  • brand: Baltimore Air Coil
  • model: Vt1-340-pcr
  • part type: Tank

Payments:

  • PayPal

Offer:

  • min. bid: $1,500.00
  • # Sold: 0
  • : true
  • quantity: 1
  • best offer: false
  • # bids: 0
  • Started: June 2, 2015, 3:02 pm

General:

  • Business & Industrial > MRO & Industrial Supply > HVAC > HVAC Units > AC & Refrigeration Units
  • condition: Used
  • in stock: Yes

Returns:

  • policy: no returns

Shipping:

  • type: Flat
  • cost: $0.0
  • handling: 10 days

Seller:

  • city: Denton, Texas
  • zipcode: 76208
part type: tank,
category: business & industrial > hvac > hvac units > ac & refrigeration units, sku: 6541297357766121,
Baltimore Air Coil VT1-340 Is Similar To:
  • (51.4% similar) Back Baltimore Airfoil cooling tower 244 tons model xv 1212C 24D30 hp volt pumps size 1510 bf...(August 11th, 2015)
  • (44.4% similar) Was in operation this summer when our chiller took a dump. But this is a good solid unit. Contact me for more details. In enclosure it is impossible to get a picture of whole unit. I'll try from the roof of an adjacent building. Normal wear. Not rusted out. Media needs some cleaning and stuff like ...(November 19th, 2017)
  • (32.1% similar) Prices to be set after purchase. Manufacture: Baltimore Airfoil company model: 3333C-LM-2 serial U071882501 double cell unit. L 10'-820HP motor, pump, plumbing, etc...(July 6th, 2018)
  • (50% similar) Model 3455A-MM800 ton sized degree delta at 640 intact inside, free of all debris...(May 7th, 2017)
  • (34.6% similar) Make offer, must go. For sale is one used good working condition back cooling tower being taken out of service because of a move and change of equipment...(November 12th, 2015)
  • (33% similar) English resource library file 545 . This machine can be seen by apt prior to buying. Motors premium efficient FD duty fan motors are standard. Owners save money while conserving natural resources and reducing environmental impact. All info should be independently verified. Benefits induced draft ...(October 29th, 2016)
  • (29.8% similar) GM of water from 128 f to 95 f at 80F entering Air wet bulb fan motors one hp fan motors, totally enclosed 1 speed 1 winding suitable for 460 volt, 3 phase, 60 hertz electrical service manufactured still installed at factory available for inspection equipment summary forced draft, counter flow ...(August 8th, 2016)
  • (23.8% similar) Rubber hose fittings and valves spare cooling tower drive shaft. Cooling tower control panel. German Krupp 10 model l pump 610 M20 b German Krupp 12' primary pump. Pact hep 60 hp lesson 60 hp...(December 28th, 2015)
  • (30.9% similar) All equipment sold as is and where is. Used back cooling tower model 3501C serial U111101503 01 nominal tons 485 motor 30 hp year cross flow open loop galvanized top and bottom with fiberglass sides price is loaded on buyer truck...(April 4th, 2016)
  • (34% similar) Across wet deck surface patented the standard polyvinyl chloride PVC across wet deck surface is designed for maximum heat transfer with low fan power requirements. The entering water temperature must not exceed 120 degrees f or damage to the wet deck material may occur, resulting in lost cooling ...(March 30th, 2016)
  • (33.6% similar) Please with questions...(September 23rd, 2016)
acrfrigeratio logo
1 offer $11399.99 USD
  • Used. Offer #1 priced at $11399.99 + $Calculated shipping estimate = $11399.99* total. +$Calculated shipping

Copyright © acrfrigeratio.com